Test Results
Two samples were submitted to Colloidal Science Laboratory on 9-7-05.
Sample 1 was made 4-7-05.
Sample 2 was made 9-2-05.
Sample 1 total silver solution concentration is 13.5 ppm
Sample 2 total silver solution concentration is 19.0 ppm
Sample 1 size distribution: 87.3% of particles are 3.15 nanometers
Sample 2 size distribution: 96.5% of particles are 2.07 nanometers
Size Distribution Report in pdf format:
Comments from Frank Key:
Jim,
The pdf file is attached for the size report. The 19 ppm sample is a result of impurities in the water that provided the anions to allow a
higher level of silver ions. The 13 ppm sample is representative of silver ion saturation in pure water.
Regards,
Frank
The "ionic silver" and "colloidal particle" ratio has not been determined yet. It is likely that the particle content is much less than 10%.
It is interesting that the Hanna PWT (pure water tester) readings in uS (micro Siemens) are very close to the actual silver ppm readings.